MAX-480Z

MAX-480Z

PA multi-zone amplifier

  • Class D amplifier and SMPS switched power supply, 480 W RMS
  • 5 Speaker output zones with volume control
  • Bluetooth/USB/FM player
  • Emergency and mute input for connection to alarm and evacuation systems
  • 24 V attenuators priority
In stock
Please sign in to see your price

This product cannot be added to the
cart because you are not logged in.

Add to wish list Compare

MAX-480Z multi-zone PA amplifier: power and control for your projects

The MAX-480Z is a multi-zone PA amplifier with 480 W RMS power and Class D design, ideal for projects requiring advanced sound control in multiple areas. It features a built-in Bluetooth/USB/FM player and multiple inputs for microphones, emergency systems and auxiliary sources, making it a versatile and efficient tool for professional installations.

Unrivalled advanced performance and versatility

  • High power and clarity of sound: 480 W RMS with a response of 45-22,000 Hz and minimum distortion (THD+N: <0,5%).
  • Multi-zone management: Individual volume control and switch-off in 5 zones, plus 100 V, 70 V and 4 Ω outputs.
  • Full connectivity: Inputs for microphones (with 48V phantom), remote panel, emergency systems, AUX and integrated player.
  • Priority and security: Includes ring tones, Chime generator, emergency priority and 24 V attenuators for alarms.

Why choose the MAX-480Z for your projects?

  • Reliable and efficient design: Its compact and lightweight construction (11 kg) includes induction cooling, ensuring quiet and maintenance-free operation.
  • Integrated protections: Soft start system, overcurrent, overload, temperature and short-circuit protection.
  • Easy integration: Compatible with RJ45 cables for remote panels and zone microphones, up to 200 m in length.

The MAX-480Z is the ideal choice for installers and engineers looking for a multi-zone PA amplifier with high performance, reliability and advanced control options for demanding projects.

Amplifier
Features
  • 100 V, 70V and 4 Ω outputs
  • 24 V attenuator priority
  • 3 auxiliary inputs
  • 3rd wire output (100 V) with attenuator priority
  • 5 output zones with volume control and Off
  • Bluetooth/USB/FM player
  • Class D PA amplifier and SMPS switch-mode power supply
  • Emergency and mute input for connection to alarm and evacuation systems
  • Input for remote wall panel
  • Microphone inputs with mix, gain and priority level control
  • Ring tone generator (Chime)
  • Tone controls
  • ZONEMIC-6 zone microphone input
Power
  • 480 W RMS
Response
  • 45-22,000 Hz (-10 dB)
Distortion
  • THD+N: < 0.5% @ 1 kHz
S/N ratio
  • Mic >75 dB, Line >83 dB, Aux >81 dB
Player
  • 5.3 Bluetooth
  • Autoplay, playback starts automatically when power is switched on
  • Bluetooth/USB/FM player for ambient music playback
  • Memory of last selected mode
  • Play mode memory (random, repeat)
Maximum humidity
  • 90%
Inputs
  • 1 x Amp-in. RCA connector. signal level 1.2 V RMS (+ 1.5 dBV)
  • 1 x emergency. Euroblock connector. Signal level: line 326 mV RMS (-10 dBV) or 100 V line
  • 3 x AUX. 2 x RCA connectors. Signal level 316 mV RMS (-10 dBV) / 47.000 Ω
  • CH 1, 2, 3, 4 and 5 mic/line balanced with 48V phantom. Combo (XLR + 6.3 mm) and euroblock. Contact closure ring tones
  • Line signal level: 250 mV RMS (-12 dBV) / 100 kΩ
  • Mic signal level: 5.6 mV RMS (-45 dBV) / 600 Ω
  • Mute (Emergency Priority) by contact closure. Euroblock connector
  • Remote wall panel, RJ45, 250 mV RMS
  • ZONEMIC-6 zone microphone, RJ45, up to 200 m cable length
Outputs
  • 1 3rd priority wire for attenuators (100 V)
  • 1 attenuator priority, 24 V 100 mA and contact closure. Euroblock connector
  • 1 Pre-out. RCA connector. Signal level 1.2 V RMS (+1.5 dBV)
  • 1 REC. 2 x RCA connector. Signal level 316 mV RMS (-10 dBV). Pre-master.
  • 100 V, 70 V or 4 Ω loudspeaker output, or 5 zones of 100 V loudspeakers with 7-position volume selector and OFF (max. 240 W per zone)
Functions
  • Induction cooling, fanless. Silent and maintenance-free
  • Power ring light on volume control, AUX input, zone and player indicators.
  • Power, signal, clip, priority activation and protection indicator lights
  • Priority of inputs (in order of attenuation):
  • Ring tones (chime): on microphone inputs, by contact closure
  • · 100V Emergency Input with selectable signal level (VOX)
  • · Auxiliary Inputs | Player
  • · Channel 1 with selectable signal level (VOX)
  • · Channels 2 | 3 | 4 | 5 with shared selectable signal level CH 2-3-4-5 (VOX)
  • · Mute by contact closure
  • · Remote wall panel
  • · Zone microphone, ZONEMIC-6
Protections
  • Soft start, overcurrent, overload, temperature and short circuit
Controls
  • Aux or player input selector
  • Master volume
  • Mic/line/phantom selector, ring tones and priority
  • Microphone volume
  • Priority activation signal level (VOX)
  • Ring tone level (chime)
  • Tone: bass and treble (+/- 10 dB 100 Hz and 10k Hz)
  • Zones with power on and 7 volume positions
Impedance
  • 4 Ω, 100 V (20 Ω) and 70 V (10 Ω) line, euroblock
Temperature
  • -10 ºC ~ 40 ºC
Power supply
  • 230/115 V AC 50-60Hz, 680 W
  • Fuse AC 230 V, 6.3 A / 115 V, 12 A
Dimensions
  • 430 x 89 x 320 mm depth
Weight
  • 11 kg
Accessories
  • Bluetooth antenna
  • Power cable
  • FM antenna
  • Rack mounts
Optional
  • ZONEMIC-6: Paging microphone